There has been an increase in calls for information whether an above ground, inground, spa/hot tub, or portable pool needs permits. It needs to be buried 8 inches from the surface and return to where you started the loop to close loop. Above ground pool grounding diagramme. Continue the conduit into the trench and then into the post. Read more inspection articles like this. Keeping the electrical potential at the same level reduces the hazard created by stray currents in the pool or in the ground around the pool.

Above Ground Swimming Pool Grounding

The following must be grounded: Grounding and bonding terminals should be identified as being used for wet and corrosive environments. Bonding and grounding are two of the most essential electrical safety tasks pool owners must perform. Standards of Practice, an inspector is not required to inspect swimming pools or spas. Setting a time clock is simple.
Luminaries and related equipment should also be grounded. Connect an 8-gauge wire to the metal posts of the pool, the pump, and the metal plate on the skimmer and then wire that to the pump to bond the entire pool. For urgent questions, you can reach us directly at 1-800-288-7946. Shells and brackets of all pool lighting. I don't have the filter plugged in when we are in the pool.

Above Ground Pool Grounding Diagrammes

Pool pumps are wired to run on either 230V or 115V. Exposed wiring behind the missing Intermatic Insulator Cover in a timer clock, can easily throw 220 volts onto wet (or dry) fingertips. Inside the box you'll see a 24 hour dial. The pool water itself, which you can achieve by adding a pool ladder to your pool and bonding it to your bonding grid. Freight charges may apply on oversized products. All fixed metal parts must be bonded, including metal-sheathed cables and raceways, metal piping, metal awnings, metal fences, metal doors, and metal window frames. This charge naturally wants to balance out by flowing toward materials that have a neutral or positive charge. Above ground swimming pool grounding. This is because the electric current is seeking the path of least resistance toward a positive charge. Older pools, built before 1975, may not have wiring that conforms to NEC Article 680.

If they are turning, check that the dial is not bent, which would prevent the trippers from contacting the switch as they come around. We also support your local pool professionals to help them to create a safe pool installation. Pool lights would not illuminate the water in the evening. An equipment-grounding conductor should be installed with the feeder conductors between the grounding terminal of the pool equipment panelboard and the grounding terminal of the applicable service equipment. This allows the electricity to dissipate, preventing electrical shocks and keeping you and your loved ones safe. How to Wire an Above-ground Pool Pump. They also should be listed for direct burial. How do bonding and grounding work together in a pool? Bonding and grounding work together to provide an important element of pool safety. Link provided here and below to our complete Bonding package which includes instructions and all components required. The video below teaches you how to install a skimmer bonding plate and explains a lot of what is also on this page. We commonly set time clocks to operate 10 - 14 hours per day, depending on the efficiency of the system, amount of debris and pool use. Don't stand in water when working with or inspecting electrical equipment. Even if you have a temporary pool like an Intex pool, please take the time to put in a proper dedicated GFI Plug/Outlet and bond the pool and equipment.

Grounding An Above Ground Pool By Code

If you want to learn more about how to keep your pool up to code and safe to use, you'll want to research your specific area's code requirements. Steps: - Working with electricity around a pool can be dangerous. But if a wire is broken or frayed, or if a piece of equipment malfunctions, it can create a short circuit (or fault) that makes electricity flow down a path it isn't supposed to. If you happen to touch both the motor and another surface with lower charge, the electricity will flow through you as it seeks the ground. Follow the instructions on the inside of the heater or consult the owner's manual for instructions specific to your heater model. Bonding is also known as equipotential bonding because the goal of this process is to equalize the potential differences in voltage between different parts of your pool equipment. How To Bond A Pool - Above Ground Swimming Pool Bonding Information. I commonly advise pool owners to operate the filter system during the day, so that processes are active while the sun is beating down and the pool is most likely to be in use. A properly connected pool electrical system is an important but largely unknown element of pool safety.

Water and electricity are a dangerous combination, installing a pool bonding wire helps mitigate the danger. Poured concrete, sprayed concrete, and concrete block with coatings must be considered conductive materials. Be sure to identify all circuits that are related to the pool equipment. The terms bonding and grounding are often used together, and in many cases, they're used interchangeably. Using pool pump timer clocks makes good sense. In the majority of cases, an electrician will ground your pool equipment by attaching a ground wire to the electrical panel that supplies power to your pool systems. Understanding Bonding and Grounding for Swimming Pool Equipment. We also offer manuals, literature, and brochures on the Hayward website. All lighting assemblies and luminaires must be connected to an insulated copper grounding conductor not smaller than 12 AWG.

Above Ground Pool Grounding Diagramme

If the bird could reach a different potential, like a ground wire or a wire with a different current/potential, then current would flow through the bird, and it would fry like a piece of chicken at Kentucky Fried Chicken, maybe Popeyes for you Southerners. Time needed: 1 hour. It is important to remember that water and electricity don't mix. Attach bonding lugs to pool. Determine how much #8 bare solid copper wire you will require for the job and how many bonding lugs. But bonding and grounding are actually two totally different processes. Grounding an above ground pool by code. After 20 years of service, the conduit, (also called Liquid Tight), and the connectors may crack and expose the wires and motor to moisture. When inspecting the pool or spa, check for unfinished or poor workmanship, particularly with the electrical components, wiring and installation. This 'wire harness' is the (usually) flexible conduit that encases the wires that lead from the timer clock or switch to the pool pump motor. To convert to a dual speed pump, you'll need to add the fourth wire, and switch out the time clock to a two speed clock, or the PE153 digital time clock, which can accept the fourth wire. If you don't have experience working with electricity, installing your own ground wires or bonding grid could put you at risk. Maybe the local pool store has a list of installers in your area who are familiar with what to dolinadu said:I felt it one day last week and also today. According to InterNACHI's Home Inspection. When electricity is properly connected, your pool is up and running!

Your pool professional's licensed electrician is familiar with pools. Can I Bond and Ground My Own Pool? When wiring a single speed pool pump motor of either voltage, 3 wires bring power from the breaker, timer or switch, and connect to the terminal board of the motor. Unless you are an electrical engineer or electrician, you probably don't think much about your pool's electrical system. Aboveground pool pumps are often 115V only, wired with a power cord, and plugged into a GFCI outlet. FREE Standard Shipping On All Orders! Intermatic timers have a visual inspection window to look at the timer mechanism and see if the gears are turning. It is that "flow" of electricity that provides power to devices like lights, vacuums and swimming pool pumps. But they are just one element of an overall bonded and grounded pool electrical system. Connecting (or bonding) everything metallic in and around the pool will help eliminate voltage gradients (or differences in electrical potential) from one part of the pool to another, and from metallic equipment to the pool water.

An electrician bonds pool equipment by connecting it all together with conductive wire also known as a bonding wire when it comes to pools. Connections of bonded parts must be made in accordance with the NEC® (refer to Section 250. Doing that requires drilling a hole, so I usually use a stainless self-tapping screw and have only been made to replace them once with the "required" hardware. Gas Pool Heaters can be wired with either 110V or 220V, but they don't need their own timeclock or even their own breaker. First off, don't mess around with the wires while the power is on – shut off ALL of the breakers, and the time clock. Wet-niche luminaires supplied by a flexible cord must have all exposed non-current-carrying metal parts grounded. They can be – but they are usually powered by tapping off of the pool pump time clock, bringing in two power wires and a ground wire. Use caution and common sense when operating your equipment. Lastly, it is the law! Before doing any electrical work, ensure the power is turned off at the circuit breaker.

Like the other parts of your home, swimming pools require electricity to function. Electrical bonding and grounding are among the important safety features provided by pool installation professionals to ensure your family's safety. Without a grounding system in place, people or pool equipment may become the conductor. Another pool feature that is not noticeable but is critical to your family's safety is bonding and grounding of the pool's electrical system. If any wires are exposed or protective casings or housings cracked, it's time to do something. Feed three individual 12-gauge wires through the conduit into the post. Loose wiring and cover plates, broken conduit and connections can be hazardous.